{"product_id":"schichten-pufferspeicher-schoenberg-spsrr-800-714-l-2-waermetauscher","title":"Layered buffer tank Schönberg SPSRR 800, 714 l, with 2 heat exchangers","description":"\u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Schönberg SPSRR 800 is a stratified buffer tank for heating water with two integrated heat exchangers. It is suitable for heating systems in which multiple heat generators, separate heat exchanger circuits, or different heat sources are to be integrated into a storage system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe stratification technology supports an orderly temperature distribution in the tank. The SPSRR 800 features an upper heat exchanger with a surface area of 2.4 m² and a lower heat exchanger with a surface area of 3 m². For hydraulic integration, eight 1 1\/2\u0026quot; female threads are available for charging and discharging. Four 1\/2\u0026quot; female threads allow the integration of sensors and controllers.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThanks to the two integrated heat exchangers, the tank can be used flexibly in systems with separate circuits. The multiple connection areas facilitate system-specific integration of charging and discharging, sensors, venting, and electric backup heating. The available insulation variants allow adaptation to energy efficiency, installation dimensions, and installation situation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe SPSRR 800 is intended for heating water and can be used in heating systems with wood heating, solar thermal systems, other heat generators, and, with proper hydraulic design, also as a buffer tank in heat pump heating systems. The integrated heat exchangers support separate circuits, while the direct tank connections are used for the hydraulic integration of the heating water circuit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eSPSRR 800\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage tank type\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eStratified buffer tank\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNet capacity without heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e714 l\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNumber of heat exchangers\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeat exchanger surface area (top)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2.4 m²\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeat exchanger surface area (bottom)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 m²\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure tank\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage tank material\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eQuality steel S235JRG2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e790 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight with insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,690 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eTipping dimension without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,720 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e220 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLoading \/ unloading connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e8 x 1 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSensor \/ controller connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4 x 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVentilation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/4\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eConnection for electric heating element\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2 x 1 1\/2\u0026quot; female thread, tank center and tank bottom\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eInsulation variants\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eEPS 100 mm, EPS 130 mm, STS Vacuum Plus 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe tank must be transported and installed upright, dry, and secured against tipping over. The installation site must be load-bearing, level, frost-free, and sufficiently accessible for connection, testing, and maintenance work. Hydraulic connection, pressure testing, and commissioning must be carried out by qualified personnel or a specialized company.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eElectric heating cartridges may only be mounted on the designated red-marked connections. Before installation, the installation length, electrical data, fuse protection, and suitability of the heating cartridge must be checked separately. The insulation should only be installed after the unit has been set up, connection work has been completed, and a leak test has been performed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eSchönberg SPSRR 800 stratified buffer tank\u003c\/li\u003e \u003cli\u003eInsulation depending on the selected version\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Schönberg","offers":[{"title":"100mm","offer_id":58216617902428,"sku":"SPSRR800+EKKC","price":1523.56,"currency_code":"EUR","in_stock":true},{"title":"130mm","offer_id":58216618000732,"sku":"SPSRR800+EKKB","price":1713.36,"currency_code":"EUR","in_stock":true},{"title":"150mm","offer_id":58216618099036,"sku":"SPSRR800+EKKA","price":1888.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-schichten-pufferspeicher-spsrr-1500_2f05201c-64b9-4f40-90d4-c47e142d1871.jpg?v=1783930945","url":"https:\/\/lv.gemashop.de\/en\/products\/schichten-pufferspeicher-schoenberg-spsrr-800-714-l-2-waermetauscher","provider":"GEMA Shop","version":"1.0","type":"link"}