{"product_id":"holzvergaserkessel-attack-slx-40-lambda-touch-40-kw","title":"Attack SLX 40 Lambda Touch wood gasification boiler 40 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Attack SLX 40 Lambda Touch 40 kW wood gasification boiler is a powerful log wood boiler for the central heat supply of single-family homes, holiday homes, workshops, small businesses, and comparable buildings. It operates on the wood gasification principle and is designed for dry log wood, when a robust wood heating system with modern control and buffer tank integration is sought.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe ATTACK SLX 40 Lambda Touch uses a steel boiler body with wood gasification, induced draft fan, refractory concrete nozzle, tubular heat exchanger, and turbulators. The Lambda Touch control works with a lambda sensor and touchscreen and controls the combustion process via relevant operating values such as oxygen content, boiler temperature, and flue gas temperature. In the Lambda Touch version, automatic cleaning of the heat exchanger via the turbulators is provided.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe Lambda Touch control makes operation easier because important operating information is displayed directly on the touchscreen and the combustion process is automatically adjusted. The generous design of the SLX series supports longer burn times, while the turbulator technology supports cleaning of the heat exchanger during operation. This makes the boiler particularly suitable for operators looking for a powerful wood heating system with modern control and clear system integration.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe wood gasification boiler is intended for operation in a professionally planned heating system with a buffer tank. For the SLX 40, a buffer tank is recommended so that the generated heat can be properly absorbed and released to the heating system as needed. For the return temperature, a suitable return temperature raising or mixing device must be planned.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003cp\u003eThe most important technical data of the Attack SLX 40 Lambda Touch are summarized below.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e40 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003edry firewood, 12 to 20% moisture content\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCombustion technology\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003ewood gasification\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90.4%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMaximum operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating water temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e65 to 85 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e650 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDimensions\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1472 × 703 × 1506 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMaximum log length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e750 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDraft requirement\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e23 Pa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue gas temperature at rated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e165 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue pipe connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e150 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety heat exchanger\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003epresent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRecommended buffer tank volume\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3000 l\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eElectrical connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V \/ 50 Hz \/ 10 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption at rated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e78 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eProtection class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eIP 20\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlow \/ return\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eG 2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe boiler should be installed by a qualified specialist company. For operation, a suitable chimney connection, sufficient combustion air, an appropriate heating system, the integration of a buffer tank, and a return temperature increase must be taken into account. For the output range SLX 40 to SLX 55, the size DN32 is provided for the ATTACK OVENTROP connection.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe power selection must match the heating load of the building and does not replace a heating load calculation. The boiler is designed for dry firewood; wood moisture and fuel size have a direct impact on operation, output, and combustion quality. Installation in living spaces and hallways is not intended.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eATTACK SLX 40 LAMBDA Touch wood gasification boiler\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Attack","offers":[{"title":"Noklusējuma nosaukums","offer_id":49551578890588,"sku":"ASLXL40","price":6212.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXlambda-webrender.webp?v=1774512431","url":"https:\/\/lv.gemashop.de\/en\/products\/holzvergaserkessel-attack-slx-40-lambda-touch-40-kw","provider":"GEMA Shop","version":"1.0","type":"link"}